- 11 - Use, maintenance and installation instructions
TEC 30D EV
INGLESE 8.fm
GB
(*)The equipment has undergone acoustic emissions testing at the independent and
qualified DNV Modulo Uno laboratory, which issued the appropriate certification of com-
pliance based on Directive 2000/14/EC.
Noise level
Level of LwA sound power
(measured and guaranteed)
db(A) 84 (*)
Level of LpA acoustic pressure
(measured at 7m)
db(A) 59 (*)
Starter battery characteristics
Minimum battery capacity A/h 60
Battery voltage V DC 12
Fuse for equipment electrical system
protection
A 150
Generator technical data
Maximum output (continuous) W 2500±5%
Output voltage V 230±10%
Frequency Hz 50
Insulation Class H
Table 2: Electrical cable diameter
Description
Unit of
measurement
Value
Equipment connection cable – electricity line (230V) mm
2
2,5
Equipment connection cable - battery charger mm
2
2,5
Equipment connection cable – starter battery (cable
length up to 6 m)
mm
2
16
Equipment connection cable - starter battery (cable
length more than 6 m)
mm
2
25
Table 1: Technical specifications of the equipment