The unit tends to shut
down
Requested power higher than
2,5 kW
Decrease the required voltage
load
Air filter blocked Clean the air filter
Oil level too high
Check the oil level, and remove
excess oil if necessary (See “Do
not mix oils with different cha-
racteristics or from different
manufacturers.”)
The inverter is broken Contact the service department
Malfunction in the pump power
supply
Contact the service department
Injectors dirty or faulty Contact the service department
The unit is not delivering
power
The power cables are
disconnected or they do not
provide a continuous supply
Contact the service department
The inverter is broken Contact the service department
The power supplied is not
constant
Requested power higher than
2,5 kW
Decrease the required voltage
load
Air filter blocked Clean the air filter
The power cables are
disconnected or they do not
provide a continuous supply
Contact the service department
The inverter is broken Contact the service department
Malfunction in the pump power
supply
Contact the service department
Injectors dirty or faulty Contact the service department
The battery charger does
not supply voltage
Damaged battery charger fuse
Replace fuse (See “Replace-
ment of fuses”)
Table 6: Operation failures