14 EPT058613 Issue 1 March 2020
INTERLOCK SWITCHES
Interlock switches must be fitted to all access guards preventing access to the laser output
lens and marking area that can be opened without the use of access tools.
Interlock switches must be wired into the laser control circuit so that the laser beam is
disabled when the guard is removed.
Emergency Off
Integrate the laser into the emergency off circuit of the machine into which the laser is
integrated. Install an emergency off push button near the laser marking systems which
turns off the laser. Connect the emergency off push button via the interlock circuit to the
controller.
GUARDING LABELS
Domino recommend that the following information is prominently displayed on the guard:
WARNING: Class 1 laser product containing an embedded class 4 laser.
Operation of the product with safety guards removed may result in
hazardous exposure to laser radiation.
These labels are supplied with the laser system. Additional labels are available from
Domino Printing Sciences plc as part of the Guarding Labels Kit, Part Number L007628.