2.3 Telephone Entry System Wiring and Adjustments
Door ControlGate Control
Main Terminal
Door Locks
Gate Operator
Power for electric strike or ma
g
netic
Magnetic lock is wired to
the Normally Closed (NC)
relay input.
Electric strike is wired
to Normally Open (NO)
relay input.
Gate Operator
is wired to
Normall
y
O
p
en
LkP
To a Relay Input
To a
Relay Input
Door
Lock
Wiring MUST be twisted and
completely isolated from ground.
See section 2.1.4.
“PSW” Switch Input 1 -
See section 1.6 for Postal lock connection.
A switch closure across these terminals activates
Relay 1 for its programmed strike time or dials a
preprogrammed phone number.
See section 3.1.7 Switch Input Feature.
Switch Input 2 -
A switch closure across these terminals activates Relay 2 for its
programmed strike time or dials a preprogrammed phone number.
See section 3.1.7 Switch Input Feature.
“PHONE”
“PHONE”
Central Office
Phone Line Input
touch tone, loop start
“CGND”
Earth Ground
See section 2.1.3.
Black (Neg)
White
Blue
Red (Pos)
“NO” - Normally Open (NO)
“NC” - Normally Closed (NC)
“C” - Common (C)
Relay Input 2
“C” - Common (C)
“NC” - Normally Closed (NC)
“NO” - Normally Open (NO)
Relay Input 1
Power Input
16.5 VAC, 20 VA power.
See section 2.1.1.
20 VA
Wire Size Distance
18 AWG
16 AWG
Up to 100 ft
Up to 200 ft
Wire Size Distance
24 AWG
22 AWG
Up to 800 ft
Up to 1600 ft
LCD Display Contrast Adjust
See 2.3.3
Master Code Switch
See 2.3.4
Speaker Adjust
See 2.3.1
Ring Pin Jumper
See 2.3.5
Tone On/Off Jumper
See 2.3.1
Handset/ Hands Free Jumper
See 2.3.6
Microphone Adjust
See 2.3.1
Click Sensitivity Adjust
See 2.3.2
Feedback Adjust
See 2.3.1
Factory wired on
1803 & 1810 ONLY.
Ring
Tip
LCD Display
(1803 & 1810 only)
Com
NC
Ferrite
Filter
POSTAL
LOCK BO
X
External Postal
lock connection
(Optional).
Type of wiring to be used on ALL
external devices:
A) Type CL2, CL2P, CL2R, or CL2X.
B) Other cable with equivalent or
better electrical, mechanical, and
flammability ratings.
UL 294 Tamper
Switch
Note: Located under
microphone board
(See Section 1.7).
“BAT” & “COM” - 12 VDC, .7 Ah, SLA Standby Battery Input
Battery must power system at least 30 minutes to comply with Canadian certification
(Battery not supplied).