26
1800-060 Issued 7-19
Version A
0
? ? ? ?
8
0
0
0
1
? ? ? ?7
1
? ? ? ?
3
0
0
1 2
1. Press and enter your four-digit MASTER CODE (beep).
2. Press (beep) for a single system, OR (beep) for multiple systems.
3. Press together to end this programming sequence (beeeeeep).
0
0
1
4
0
? ? ? ?
0
This program sequence sets the telephone entry system to operate as a single unit on the phone line, or to share the phone line
with other units. If multiple systems are sharing the same phone line, then each one must be set as a “multiple system” and
each must have a unique master code.
Factory setting = 0 (Single System)
3.1.2 Single or Multiple Systems
These steps will program Relay 1 and Relay 2 strike times. Strike times can be programmed from 1/4 second (enter 00 in step
3) up to 99 seconds by entering the desired time in seconds.
Factory setting for relay strike times are: Relay 1 = 01 (1 sec), Relay 2 = 01 (1 sec).
3.1.3 Relay Strike Time
1. Press and enter your four-digit MASTER CODE (beep).
2. Press (beep) to set Relay 1, OR (beep) to set Relay 2 strike time.
3. Enter the two-digit strike time in seconds (00-99), then press (beep).
(Example: 1/4 second - enter 00, 1 second - enter 01 etc.)
4. Repeat steps 2 and 3 to set other relay strike time.
5. Press together to end this programming sequence (beeeeeep).
Important Note: If you make a mistake while programming, press keys at the same time
to escape from programming no matter how much has been completed, then begin again at step 1.
The following programming sequence turns the “Tone Open” sound either On or Off (when the relays activate). This feature is
available on Rev L boards or higher. See 3.1.6 for information about “Tone Open” numbers feature.
Factory setting = 1 (tone ON)
3.1.4 “Tone Open” Sound ON or OFF
1. Press and enter your four-digit MASTER CODE (beep).
The 1803 & 1810 LCD display will read: 1=Y 0=N
2. Enter for YES - tone will sound or for NO - tone will not sound, then press (beep).
3. Press together to end this programming sequence (beeeeeep).
This programming sequence sets the maximum time allowed for conversation when the entry system places a call to the
resident. The talk time can be set from 1 second up to 255 seconds (4 minutes, 15 seconds) and is entered as a three-digit
number in step 3. The talk time set here DOES NOT affect the telephone numbers that are programmed under directory codes
0, 00, 000, 0000 and 1, 01, 001, 0001. The talk time for these two directory code sets are factory set to the maximum. Phone
numbers programmed under these directory codes should be reserved for management or emergency phone numbers that
generally require longer conversations.
Factory setting for talk time = 060 (60 seconds).
3.1.5 Talk Time
1. Press and enter your four-digit MASTER CODE (beep).
2. Enter the three-digit talk time in seconds (001-255), then press (beep).
(Example: 1 second - enter 001, 20 seconds - enter 020 etc.)