37
1800-060 Issued 7-19
Version A
1. Press and enter your four-digit MASTER CODE (beep).
2. Enter the five-digit divide number, then press (beep).
3. Press together to end this programming sequence (beeeeeep).
1. Press and enter your four-digit MASTER CODE (beep).
2. Press then press (beep).
This programming sequence will automatically end itself by a long (beeeeeep).
1. Press and enter your four-digit MASTER CODE (beep).
2. Enter the five-digit entry code to be deleted, then press (beep).
3. Repeat step 2 to delete additional entry codes.
4. Press together to end this programming sequence (beeeeeep).
1. Press and enter your four-digit MASTER CODE (beep).
2. Enter the five-digit entry code, then press (beep).
3. Repeat step 2 to enter additional entry codes.
4. Press together to end this programming sequence (beeeeeep).
? ? ? ?
9
0
? ? ? ?
1
1
9 9 9 9
1. Press and enter your four-digit MASTER CODE (beep).
2. Enter a single-digit hold code number (1-4:Relay 1, 5-8:Relay 2), then press (beep).
3. Enter a four-digit entry code, then press (beep). Fill in table below and in back of this manual.
4. Repeat steps 2 and 3 to enter additional Hold four-digit entry codes (up to 8 codes total).
5. Press together to end this programming sequence (beeeeeep).
? ? ? ?
9
1
0
0
0
0
This programming sequence programs five-digit entry codes into the system memory. The number of five digit entry codes that can be
programmed is limited to six. We suggest that all entry codes that are programmed into the system be listed with the names of residents
that they have been assigned to (see log tables in back of this manual).
3.3.6 Programming Five-Digit Entry Code
The five-digit entry codes can be made to activate either relay 1 or relay 2 by programming a five-digit divide number. Five-digit entry
codes equal to or less than the divide number will activate relay 1. Five-digit entry codes greater than the divide number will activate
relay 2.
TIP: you can make ALL five-digit entry codes (except 0000) activate Relay 2 by programming divide number 00000, or make ALL
five-digit entry codes activate Relay 1 by programming divide number 99999.
Factory default divide number is 99999 - Activates Relay 1.
3.3.9 Five-Digit Entry Code Divide Number to Activate Relays
3.3.7 Delete Individual Five-Digit Entry Code
3.3.8 Delete ALL Five-Digit Entry Codes
This programming step deletes ALL five-digit entry codes that have been programmed into the system.
CAUTION: This programming CANNOT be UNDONE!
A four-digit entry code can be programmed to reverse the condition of relay 1 or relay 2 ONLY. If a relay is NOT activated, entering one of
these entry codes will activate it and keep it activated (Hold). If a relay is activated, entering one of these entry codes will release it.
(4) entry codes can be assigned to each relay using specific Hold Code numbers. DO NOT use existing four-digit entry codes that were
programmed in from section 3.4.1. Rev P circuit board or higher ONLY.
Hold four-digit entry code will override any hold open sequence that is in progress and close the gate immediately.
Hold code numbers 1 through 4 are assigned to Relay 1 ONLY (one four-digit entry code per hold code number).
Hold code numbers 5 through 8 are assigned to Relay 2 ONLY (one four-digit entry code per hold code number).
3.3.5 "Hold Four-Digit Entry Codes" - Reverse Relay Activation ONLY
1
2
3
4
Relay 1 Hold Code Hold Four-Digit Entry Code
5
6
7
8
Relay 2 Hold Code Hold Four-Digit Entry Code
? ? ? ?
0
1
? ? ? ?
3
1