26
1838-065 Issued 3-19
Version D
When elevator control is in use, an access device such as a card reader must be installed in the elevator car to allow residents
access to the floors in the building. The time interval that the button(s) is “live” after the resident activates the access device is
dependant on the revision level of the 1830 series circuit board, not the 2348 elevator control board. The relay time interval for
1830 series circuit boards with revision level A-E is set at 7 seconds. The time interval can be programmed from 1 – 254
seconds on boards with revision level F and higher.
Factory setting = 007 (7 seconds)
3.2.4 Resident Elevator Button Relay Time
1. Press and enter your four-digit MASTER CODE (beep).
The OPTIONAL LCD display will read: RES ELE TIME xxx SEC
2. Enter the relay time in seconds using three-digits (001 – 254), then press (beep).
3. Press together to end this programming step (beeeeeep).
? ? ? ?
6
3
0
The following programming sequence turns the “Tone Open sound On or Off (when the relays activate). This feature is
available on Rev K boards or higher. See 3.3.3 for information about “Tone Open” numbers feature.
Factory setting = 1 (tone ON)
3.2.5 “Tone Open” Sound On or Off
1. Press and enter your four-digit MASTER CODE (beep).
The OPTIONAL LCD display will read: BEEP RLY OP? 0=N 1=Y
2. Enter for YES - tone will sound or for NO - tone will not sound, then press (beep).
3. Press together to end this programming sequence (beeeeeep).
? ? ? ?
5
1
1
0
0
1. Press and enter your four-digit MASTER CODE (beep).
2. Enter for 9600 baud rate or for 19200 baud rate, then press (beep).
3. Press together to end this programming sequence (beeeeeep).
The following programming sequence sets an optional slower RS-232 speed. This feature is available on Rev M boards or
higher and the Remote Account Manager Software, Version 6.4.i, must be used.
Factory setting = 1 (19200 baud rate)
3.2.6 RS-232 Speed Setting
? ? ? ?
58
0
1
0
The following programming sequence sets the switch input (main terminals #4 and #6) to either activate a relay(s) or call the
phone number programmed in directory code 0, 00, 000 or 0000. Refer to section 3.3.4 to determine which relay(s) will activate
when the switch input is activated. This feature is available on Rev K boards or higher.
Factory setting = 0 (switch input activates relay)
3.2.7 Switch Input Feature
1. Press and enter your four-digit MASTER CODE (beep).
The OPTIONAL LCD display will read: KEY IN DIAL? 0=N 1=Y
2. Enter for YES (the switch input will dial a phone number) or for NO (the switch input will activate the relay), then
press (beep).
3. Press together to end this programming sequence (beeeeeep).
? ? ? ?
8
1
0
1
0
Program from System Keypad ONLY