OPERATION Operating & Maintenance Manual
Book: 46551819 (2-11-2011) Rev B 35
WARNING
!
Do not remove pressure cap from a HOT radiator. Allow radiator to cool down
before removing pressure cap. Use extreme care when removing a pressure cap
from a liquid cooling system for the engine. The sudden release of pressure from
a heated cooling system can result in a loss of coolant and possible severe
personal injury.
Check the engine oil level. Maintain per marks on dipstick.
Check the fuel level. Add only CLEAN low or ultra low sulfur diesel fuel for maximum
service from the engine.
Check the compressor lubricating fluid level between bottom and midway of the sight glass
on the separator tank.
WARNING
!
This machine produces loud noise with doors open. Extended exposure to loud
noise can cause hearing loss. Wear hearing protection when doors or valve (s) are
open.
Close all doors to maintain a cooling air path and to avoid recirculation of hot air. This will
maximize the life of the engine and compressor and protect the hearing of surrounding
personnel.
Be sure no one is IN or ON the compressor unit.
WARNING
!
Unrestricted air flow from a hose will result in a whipping motion of the hose which
can cause severe injury or death. A safety device must be attached to the hose at
the source of supply to reduce pressure in case of hose failure or other sudden
pressure release. Reference: OSHA regulation 29 CFR Section 1926.302 (b).
Starting
Turn the POWER switch to “ON”.
Turn Power switch to “START” position to crank engine. Hold switch in “START”
position for approximately 5 seconds after engine starts.