Doosan Infracore Portable Power
1293 Glenway Drive
Statesville, N.C. 28625
www.doosanportablepower.com
Book: 46551819 (02-2011) Rev B
This manual contains important safety information.
Do not destroy this manual.
This manual must be available to the personnel who operate and maintain this machine.
OPERATION, MAINTENANCE,
COMPRESSOR MODELS
C185 - D80
MANUAL
C185 - D95
Revised (10-12)
Doosan purchased Bobcat Company from Ingersoll-Rand Company in
2007. Any reference to Ingersoll-Rand Company or use of trademarks,
service marks, logos, or other proprietary identifying marks belonging
to Ingersoll-Rand Company in this manual is historical or nominative
in nature, and is not meant to suggest a current affiliation between
Ingersoll-Rand C
ompany and Doosan
Company or the products of
e
ith
er.

Questions and Answers

  • G
    grimesbryanSep 1, 2025
    What to do if my Doosan D80 Air Compressor fails to shutdown?
    • E
      efoxSep 1, 2025
      If your Doosan Air Compressor fails to shutdown, it could be due to several reasons: * A defective discharge air temperature switch, Sep. Temp Switch, engine temp switch, or engine oil pressure switch; replace the switch. * A defective shutdown solenoid; carefully block the air inlet to stop the engine. * A malfunctioning relay; replace the relay. * A defective start switch; pull the wire off the shutdown solenoid and replace the defective item. * A wire shorted hot; repair the short.
  • P
    Patricia LewisNov 9, 2025
    What to do if my Doosan D80 Air Compressor won’t start or run?
    • J
      jenniferescobarNov 9, 2025
      If your Doosan Air Compressor won’t start or run, consider these potential causes and solutions: * Check if it's out of fuel and add CLEAN diesel fuel if needed. * Service clogged fuel filters. * Ensure the compressor oil level is adequate by adding the correct oil. * Inspect and repair or replace any loose wire connections. * Verify the battery voltage and check the electrolyte level and connections. * Address a defective alternator by replacement or repair. * Check the engine water temperature and add fluid if necessary. * Replace a malfunctioning start switch, defective D2 diode, defective discharge air temp switch, defective engine oil pressure switch, defective engine temp switch or defective separator tank temp switch. * Replace any blown fuses and check for shorts...
  • V
    Valerie JohnsonNov 17, 2025
    Why does my Doosan D80 unit shutdown?
    • H
      Hannah MillsNov 17, 2025
      The Doosan Air Compressor unit might shut down due to several reasons: * The unit is out of fuel, in which case you should add CLEAN diesel fuel. * The compressor oil level is too low, so you should add the correct oil. * The compressor oil temperature or engine water temperature is too high. For compressor oil temperature consult Table 4, and for engine water temperature, check and add coolant if needed. * There's a loose wire connection; wiggle wires at switches and connector blocks, and make necessary repairs. * A component such as the discharge air temperature switch, engine oil pressure switch, or a relay is defective; replace the switch or relay. * The engine fan belt is broken and needs replacement. * The engine oil pressure is too low; check the engine oil level and ...
  • K
    Kimberly PriceNov 24, 2025
    How to troubleshoot high compressor oil temperature in my Doosan D80?
    • T
      Thomas MirandaNov 24, 2025
      To troubleshoot high compressor oil temperature in your Doosan Air Compressor, consider the following: * Clean dirty cooler exterior surfaces. * Add oil if the oil level is low, and check for leaks. * Replace clogged oil filter elements and change the oil. * Reduce operating pressure if it is too high. * Move the unit to a cleaner environment if operating conditions are dirty. * Note that ambient temperatures above 120°F (49°C) exceed the specification limit. * Relocate or reposition the unit if it is out of level by more than 15 degrees. * Check the oil specification in the manual to ensure the correct lube oil is being used. * Close the canopy and replace the belly pan to prevent recirculation of cooling air. * Replace the thermostat in the bypass valve if it is malf...

Summary

Safety

General Safety Precautions

General guidelines and warnings for safe operation and maintenance.

General Data

Unit Specifications

Detailed specifications including model, compressor, engine, fluid capacities, running gear, and measurements.

Operation

Control Panel and Before Starting Checks

Description of the control panel and essential pre-start checks.

Starting Procedures

Step-by-step guide for starting the compressor.

Stopping and Cold Weather Starting

Procedures for safely stopping and starting in cold weather.

Maintenance

Comprehensive Maintenance Schedule

A detailed schedule for all maintenance tasks by interval.

Lubrication

Compressor Fluid Selection

Chart for selecting the correct compressor fluid based on pressure and temperature.

Troubleshooting

Common Problems and Solutions

Charts listing common issues, causes, and corrective actions for the unit.

Doosan D80 Specifications

General IconGeneral
BrandDoosan
ModelD80
CategoryAir Compressor
LanguageEnglish

Related product manuals