29 Contactor Failure
Although there are no contactors activated, there is no
signal in CNT terminal. Check CNT wiring and definition.
Check also the wiring of the CNT circuit through nor-
mally closed aux-contacts of the contactors.
Cause
Troubleshooting
1. Check if there is a stuck contactor.
2. CNN is Neutral and CNT of the DLC1 T/H board feedback that
the Contactors K1-K2 and KF gets active. check the continuity
or the voltage to these contacts.
3. For hydraulic lifts, check KM-KD-KS and the thermal protection
Contactors.
TIP: Check electrical drawings pages 2-3