13
Weight Hold Weight Beep
Enables/Disables beep when a stable or
average hold weight is achieved
Beep disabled.
Beep enabled. (default)
Battery Voltage Level
Displays current battery voltage (DC)
Green Light on when charging: > 3.35 V
Full Battery: 3.35 V
50% Battery: 3.15 V
Low Battery: 3.05 V
Charge Battery: < 2.80 V
Raw Counts
Raw counts from A/D converter
View these numbers if calibration is
unsuccessful. Refer to Calibration
Troubleshooting for interpretation of these
numbers.
Software Revision
Displays Software revision
Battery Transport Mode
Disables Scale When in Transport
Normal Power Mode
Enter Power Control Mode – when in
weighing mode, press and hold ZERO for 5
seconds to exit this mode. This mode is to
be enabled when shipping the scale.