SWING DOOR LOG BOOK
2017-11
Daily checks -
facility operator
A safety check should be performed daily by the facility
operator on each automatic door.
Activation
Walk toward the door at a normal pace. The door
should start opening before you reach a minimum of
mm from the door. If the door is an escape route,
a minimum of mm applies in the direction of
escape. If the door opens toward you, the
measurements are taken from the front edge of the
door in the fully open position. Repeat for the other side
if the door has two-way operation.
Safety Note: In order to test the safety sensors we
recommend using an approved test object measuring
mm x mm x mm high to test the door safety
as detailed in BS EN.
During the Closing Cycle
Activate the door and place the test object within the
protected sweep area of the door. The door should
begin to close. The test object should be detected
without contact and the door should reopen.
During the Opening Cycle
With the door closed, place the test object within the
protected sweep area of the door. Activate the door.
The test object should be detected without contact
and the door should remain closed or stop.
In the case of Low Energy Swing Doors
• Safety devices as described above may not be itted
but are optional
• Usually have manual activation devices
• Travel at lower speeds with lower force
• In the opening and closing direction will stop when
obstructed and continue after the obstruction is
removed
General observations
• Check there are no hazards due to crushing, shearing,
impact and drawing-in.
• Check that the opening and closing speed are not
likely to increase the risk of impact
• Check that inger guards are secure and in good
repair
• Check the door area does not present tripping or
slipping hazards
• Check all doors have correct warning and information
signs displayed
• Check the position and security of barriers
• Check operation of any manual or remote activation
• Check for distractions and obstructions in the vicinity
of the doors
Mechanical Checks
• With the door on ‘Hold Open’ setting grasp the front
edge of the door and attempt to move it horizontally
and vertically. There should be limited movement in
the door pivots
• Check all door panels for broken/cracked glass
• Check all equipment and cabling is securely ixed
If you have questions about any of the above items,
please contact dormakaba UK Service.
Safety devices for all doors should be checked by an
ADSA qualiied technician at least once a year.
If you have a problem you cannot correct, turn off the
door and call dormakaba on .
If you have questions about any of the above items,
please contact dormakaba UK Service for
assistance.
If you have a problem you cannot correct, turn off
the door and call dormakaba on .