1-1-9.1 Position suppl.valve e n Position of the supply valve proportional 0% ...
100%
1-1-9.2 Position suppl.valve closed
open
e n Position of the supply valve 1 = open 2 = closed
1-1-10 Power down speed s n Calculated power down speed if NFD is running in
energy saving mode
1-1-11 state NFC nfdMin
nfdInactive
nfdStableTime
nfdGoingDown
nfdFinished
nfdMax
d n Shows the current state of the no flow detection.
1-1-12 used setpoint d n used setpoint
1-1-13 NTC Temperature d n On board NTC temperature
1-1-14 WSD pulses tank 1 e n WSD Pulse count of the tank 1
1-1-15 WSD pulses tank 2 e n WSD Pulse count of the tank 2
1-1-16 WSD pulses tank 3 e n WSD Pulse count of the tank 3
1-2 Pumps e n Information on the operating status and measure-
ments of the selected pump
1-2-1 Operating mode e e Displaying operating mode of the selected pump
1-2-1.1.1 #0-0 Pump number 1
3
e e Selection of the pump of which the operating
mode is required
1-2-1.2.1 #1-0 Operating mode Automatic
Manual (on 10s)
Disabled (off)
e e Operating mode of the selected pump (continuous
active) - Automatic - Manual (on) - Disabled (off)
1-2-2 Pump load e n Displaying the load of the selected pump
1-2-3 Thermal fail. flags s n Displaying the activity status of all thermal protec-
tion inputs 0 = not active 1 = active
1-2-4 Running hours pump e n Displaying the total running hours per pump in
HHHHHH MM
1-2-5 Number of pumpstarts c n Displaying the total numbers of starts per pump
1-2-6 Rainwater pumps e n Information on the operating status of rainwater
pumps
1-2-6-1 Fill up to RW-p Off e e Function to fill water reservoir up to level B with
rain water.
1-2-6-2 Manual Run e e Perform a manual run for a given duration.
1-2-6-2.1.1 #0-0 Rainwater pump 1
2
e e Selection of the pump of which the operating
mode is required
1-2-6-2.2.1 #1-0 Duration (s) 1
2
3600
e e Duration of the manual run in seconds
1-2-6-3 Pump 1 e n Information on the operating status of rainwater
pump 1
1-2-6-3-1 Mode OFF
ON
e e Off: Rainwater pump 1 is not used. On: Rainwater
pump 1 is used
1-2-6-3-2 State OFF
ON
e n ON: pump is running, OFF: Pump is not running
1-2-6-3-3 Runtime 0
9000000
e n Accumulated Runtime of rainwater pump 1
Parameter
Display
text
Value
1
description
Min./Max.
Read
Write
Help text