en Disposal
Dräger DrugTest 5000 Analyzer 7
To do so the following measures are required:
Always operate the Analyzer with the AC adapter while it is
not used in portable mode. A permanent connection to the
mains power is not detrimental to the integrated battery but
maintains its performance.
Connect unit to the 12 V supply cable when using in
vehicles.
For portable operation with low battery indication, connect
the charger and fully charge battery promptly.
Keep the unit connected to the charger when storing.
For long term storage of the unit without the possibility to
connect the battery charger, charge the Analyzer
completely before storage and fully recharge the battery
every 8 weeks.
6.4 Maintenance work
We recommend that the unit be serviced on a regular basis
every 12 months.
Contact Dräger or a service organization authorised by Dräger
for maintenance.
We recommend concluding a service agreement.
7 Disposal
Dispose of the product in accordance with the applicable rules
and regulations.
8 Technical data
9 Order list
Disposing of electric and electronic equipment
According to Directive 2002/96/EC, this product
must not be disposed of as municipal waste. It is
therefore labelled with the symbol depicted here. The
product can be returned to Dräger free of charge.
Please contact your national Dräger Sales
Organisation or Dräger for more information.
Supplyvoltage 12 VDC (11 to 15 VDC)
Power input approx. 3 A
Dimensions
(W x H x D)
200 mm x 250 mm x 220 mm
Weight 4.5 kg (including battery)
Temperature
Operation
Storage and
transport
5 °C to 40 °C (+41 °F to +104 °F)
–20 °C to 60 °C (–4 °F to 140 °F)
Ports optical IRDA (printer),
PS/2 (for external keyboard or
scanner),
USB Slave (for communication with
a PC)
Measurement duration four minutes and 15 seconds
Storage capacity 500 data sets with test results
Name and description Part number
Dräger DrugTest 5000 Analyzer
including battery charger supply unit, mains
cable and Instructions for Use
3701413
with
CFG 83 26 649
Keyboard, compact
(PS/2,
dimensions approx. 28.2 x 13.2 x 2.4 cm):
"QWERTY" – key assignment English 83 15 497
"AZERTY" – key assignment French 83 15 142
Dräger Mobile Printer 83 19 310
Paper for Dräger Mobile Printer
(5 rolls)
83 19 002
Carrier bag
Dräger DrugTest 5000 Analyzer
83 25 333
Charger power supply cable (12 V)
with mains cable for EU, UK, USA, AUS
83 15 675
Vehicle supply cable (12 V)
Power cable from car on-board/cigarette
lighter socket to Dräger DrugTest 5000
Analyzer
83 12 166
USB connection cable
for communication with a PC
AG 02 661
Dräger DrugTest 5000 test kits, e.g.:
Dräger DrugTest 5000 STK-CA
Package with 20 pieces
3700791
Test kit for instructing users in the use of the
Dräger DrugTest 5000 test system, also for
quality analysis.
Package with 6 pieces (3 x Positive; 3 x
Negative)
83 23 640
Dräger DrugTest 5000 System Technical
Handbook
91 00 163
Dräger Diagnostics
Software for Analyzer configuration
contact Dräger
Services