23
EN
so when the probe is correctly positioned in the vagina
of the bitch, click the
key to take the measurement
(during this time the display shows the “Wait!message)
DOD
LASSIE
01.01.2019
11:50
Wait!
when “Wait!” is displayed (approx. 1 second), hold the de-
vice stationary as the measurement is being carried out
during this time,
f) similarly, before 2 and 3 measurement, a circular mo
-
tion in the axis of the device should be made in order to
improve the contact of the mucus with the probe elec
-
trodes and conrm with the key,
g) after the end of the measurement cycle, i.e. after the
third measurement has been conrmed, the display
shows the result in the form of the number of measured
units, e.g.
DOD
LASSIE
01.01.2019
11:50
420
Menu SaveOKList
h) after completion of the examination, the probe must be
removed from the animals vagina,
i) turn o the device,
j) disinfect the device (see section: DISINFECTION).
NOTE
It is necessary to rotate the probe inside the bitch by 360°
before each measurement during the measurement cycle
to obtain “fresh” vaginal mucus on the probe. In this way,
accurate and consistent results can be obtained each time.
SECTION 6 | ANIMAL EXAMINATION