Section 2 - Electrical Connections
Section 4 - Limit Adjustments
ADJUSTING “FULLY UP” POSITION:
1.
Place small screwdriver in groove of yellow button on motor and press vertically until it
"clicks."
2.
Raise screen by pressing UP switch. Press STOP switch when screen reaches desired
position. Then press yellow button on motor until hearing a "click", then release.
ADJUSTING “FULLY DOWN” POSITION:
1.
Place small screwdriver in groove of yellow button on motor and press vertically until it
"clicks."
2.
Lower screen by pressing DOWN switch. Press STOP switch when screen reaches desired
position. Then press white button on motor until hearing a "click", then release.
CAUTION: AT NO TIME SHOULD SCREEN BE UNROLLED ENOUGH TO EXPOSE
ANY PART OF SCREEN ROLLER
Please Note: Screen limits are factory set. Instructions below for minor adjustments only. Please check with Draper prior to resetting screen limits.
CAUTION:
- Be sure all switches are in “off” position before
adjusting limit switches.
- Be prepared to shut off manually while testing.
- Screen may be damaged by lowering it too far and
exposing roller.
- Motor must be installed so that limit switches are
pointed down.
CAUTION:
Rough handling in transit may cancel/reset motor limit
settings. To prevent viewing surface damage, be
prepared to stop descending screen if surface begins
to retract instead of stopping or if motor does not shut
off when screen has fully retracted into case.
1.
Screen operates on 110-120V, 60 Hz., 1.1 amp
current draw.
2.
Junction box is located just above the bottom
access panel at the left end of the screen.
3.
Open the access panel/trap door for access to
the junction box cover.
(See bottom access panel/
trap door opening and closing instructions below)
.
4.
Remove two
(2)
hex head screws that secure
the cover to the junction box to expose the red,
black, and white pigtail leads and the green
ground wire per wiring diagram
(Page 7)
.
5.
If optional low voltage control or video interface
control is specified and factory installed, please
refer to wiring diagram
(Page 7)
.
6.
Screen is shipped with internal wiring complete
and control switch
(es)
fully boxed. Wire to connect
screen to switch
(es)
and switch
(es)
to power supply
should be furnished by installer. Connections
should be made in accordance with attached
wiring diagram, and wiring should comply with
national and local electrical codes.
7.
All operating switches should be “off” before
power is connected.
Section 3 - Operation
•
110-120V SINGLE STATION CONTROL - 3-position UP-OFF-
DOWN switch permits operation to be stopped at any point. Factory
adjusted limit switches automatically stop screen when fully down
or fully up.
•
24V CONTROL
(optional and requires optional LVC-IV)
- 3-button UP-
STOP-DOWN switches stop at any point desired and operate in
any sequence. Factory adjusted limit switches automatically stop
screen when fully up or fully down. Installer should incorporate an
all-pole disconnect in fixed wiring available with RF or IR remote.
CAUTION: When operating for the first time, cycle unit down and up several times to confirm satisfactory operation. Be prepared to cut POWER if necessary.
•
RS232 / ETHERNET - Serial communication and network
communication optionally available.
•
KEY OPERATED SWITCHING - Two key-operated switches optionally
available with this unit:
•
Key-operated power supply switch controls power to screen a
and switches. When "off", switches will not operate screen. Key may
be removed from switch in either "on" or "off" position.
•
Three-position key switch permits the screen to be operated directly
by key. Requires screen operator to have a key.
page 4 of 7