TROUBLESHOOTING
FAULT CAUSE SOLUTION
Unit does not
operate
No power to machine.
Unit not switched on.
Plug in unit; check power at outlet and at base of unit.
Switch unit on.
Blower wheel
not turning
Obstructed blower.
Remove duct ring and grill.
Remove obstruction.
Replace duct ring and grill.
Unit operating,
but room not dry
Not enough time to dry.
Poor air movement in room.
Excessive moist air infiltration.
Allow more time for drying.
Increase air movement with air movers.
Reduce infiltration.
continuously in
defrost mode
Increase room temperature.
function
Unit collects too
little water
Room air is dry.
Room temperature is too low.
Check humidity with hygrometer.
Increase room temperature.
Check filter and coils; clean as necessary.
If the problem you are experiencing is not listed here, call your local distributor or contact the Dri-Eaz Service
Department toll-free at 800-932-3030.
SPECIFICATIONS
Model DRIZAIR 1200 F203
Type Standard refrigerant
Refrigerant R-410A
Use weight 80 lbs. | 36 kg
32 × 20 × 19.5 in.
83 × 50 × 50 cm
Power 6.8 amps, 110 volts
Water removal AHAM
(80°F/60% RH)
54 pts. | 25.5 liters / day
Water removal max.
(90°F/90% RH)
105 pts. | 49.7 liters / day
Max process air 202 CFM | 343 CMH
Operating range 33°–100°F | 1°–38°C
Air filter
3M HAF filter (part no. F368)
Power cord 25 ft. | 7.6 m
Construction
Rotomolded polyethylene housing
Safety
CE
Specifications are subject to change without notice. Some
values may be approximate.
Warranty information is available at www.dri-eaz.com.