49-130B MANUAL, DRITEC 4000i 230V AU 9 Legend Brands, Inc.
TROUBLESHOOTING
Circuit breaker trips
after a few minutes
of operation.
Reactivation outlet not ducted.
Ducting is kinked or blocked.
Excessively long ducting.
The Reactivation Out must always be ducted out of the
area being ducted.
Straighten all ducting as much as possible; remove any
blockages.
React ducting length should not exceed 20 ft. (6 m).
Unit not switched on.
No power to machine.
Switch unit on.
Check power cord connections at wall outlet and in top
compartment of unit. Check supply circuit breakers.
Unit operating, but
room not dry
Not enough time to dry.
Poor air movement in room.
Excessive moist air infiltration.
Allow more time for drying.
Increase evaporation with air movers.
Seal off area to reduce infiltration.
Unit removes too
little water
Room air is dry.
Inlet air temperature is too warm.
Inlet air temperature is too damp.
Filter is clogged.
Confirm humidity level with hygrometer.
Decrease temperature of intake air.
Decrease humidity of intake air.
Check filter. Clean or replace as necessary.
If the problem you are experiencing is not listed here, call your local distributor.
Process air (at 27°C/60%RH)
Water removal (at 27°C/60%RH)
41.2 L / day | 87 pts. / day
84.1 × 53.7 × 51.4 cm
(With handle upright = 107.3
cm.)
33.13 × 21.14 × 20.25 in.
(With handle upright = 42.3 in.)
PARTS INCLUDED
• Reactivation Out duct ring adapter
• Reactivation Out heat-resistant ducting, 6 m x 150mm
(20 ft. × 6 in.)
• 150 mm (6 in.) duct clamp
• Air inlet duct ring adapter (optional, installation re-
quired)
• Process air outlet layflat duct adaptor assembly (op-
tional, installation required)
• Power cord, 7.6 m
OPTIONAL
Layflat ducting for process air outlet (F536)
FOR PARTS AND SERVICE CALL YOUR LEGEND
BRANDS DISTRIBUTOR
Warranty registration procedures vary by country/market.
Contact your local distributor for assistance.