07-01480F F292-A 6 Dri-Eaz Products, Inc.
TROUBLESHOOTING
FAULT CAUSE SOLUTION
Unit does not
operate
No power to machine.
Unit not switched on.
Plug in unit; check power at outlet and at base of unit.
Switch unit on.
Compressor will
not start
Unit needs 5 minutes before restart
Overload preventing start up
Switch off unit, wait 5 minutes before starting.Reduce
room temperature to 90°F (32°C) or less.
Blower wheel
not turning
Obstructed blower.
Remove duct ring and grill.
Remove obstruction.
Replace duct ring and grill.
Unit operating,
but room not dry
Not enough time to dry.
Poor air movement in room.
Excessive moist air infiltration.
Allow more time for drying.
Increase air movement with air movers.
Reduce infiltration.
Unit
continuously in
defrost mode
Room temperature too low
Increase room temperature.
Pump does not
function
Stuck float valve
Clean float valve shaft.
Unit collects too
little water
Room air is dry.
Room temperature is too low.
Airflow through unit is restricted
Check humidity with hygrometer.
Increase room temperature.
Check filter and coils; replace filter and clean coils as
necessary.
If the problem you are experiencing is not listed here, call your local distributor or contact the Dri-Eaz Service
Department toll-free at 800-932-3030.
SPECIFICATIONS
Model Evolution LGR F292-A
Type LGR
Refrigerant R-410A
Use weight 92 lbs. | 42 kg
Power 5 amps, 115 volts
70 pts. | 33 liters / day
Max process air 160 CFM | 272 CMH
Operating Range 33°F100°F | 1°C33°C
Air filter
4-PRO filter (part no. F590)
Power cord 25 ft. | 7.6 m
33.5 × 20.7 × 20.7 in.
85 × 52.5 × 52.5 cm
Construction Rotomolded polyethylene housing
Safety
ETL certified to CSA 22.2 no. 92
Specifications are subject to change without notice. Some
values may be approximate.
WARNING: This product may expose you to
chemicals, including lead and phthalates, known
to the State of California to cause cancer, birth defects,
or other reproductive harm. For more information, go to
P65Warnings.ca.gov
Warranty information is available at
LegendBrandsRestoration.com.

Related product manuals