07-02300C F600 4 Dri-Eaz Products, Inc.
USER SETTINGS
Only menu items followed by a greater-than symbol (>) can be adjusted. If no keys are selected for 5 minutes on screens: INLET
OUTLET, GRAIN DPR (INLET-OUTLET for 230V models), the display will return to normal display mode. In all the other menu items,
the display with return to the normal display mode after 20 seconds. Items without the symbol (>) are for information only and cannot be
changed or reset. See “System Messages” below for additional system status messages.
Press DISPLAY
MENU to proceed to
the next menu item. ↓
Press ˃ MENU SELECTION to change the setting. →
1. JOB HRS RESET >
PWR INTERRUPT X
1. JOB HR RESET 0
PWR INTERRUPT 0
2. INLET OUTLET
100ʹ 80% 115ʹ 30%
Unit displays GPP if set to Fahrenheit or g/kg if set to Celsius. To change this setting, see menu item 9.
4. FILTER CHECKED
XXX HRS >
Press ˃ to clear filter hours.
5. COIL CLEANED
XXX HRS >
Press ˃ to clear coil hours.
Press ˃ to turn ON or OFF. For maximum dehumidification, make sure
HUMIDISTAT is OFF.
7. HUMIDISTAT
SETPOINT XX% >
Press ˃ to cycle through 40%–90% at 5% increments (default is 50%).
Press ˃ to change
language options.
Press ˃ to change to °F or °C.
12. FIRMWARE
3.XX FXXX-XXX
(Returns to
top menu item.)
The following section available only on wireless-equipped units.
(Returns to
top menu item.)
AT THE END OF THE JOB
To reduce the possibility of drips when moving the
unit, follow these additional steps to ensure that all
water is removed from the unit.
NOTICE: The unit will complete the defrost cycle even if
the unit is turned off but still plugged in. If the unit is
unplugged during the defrost cycle, excessive water may
accumulate in the unit and may drip out when you move
the unit.