TROUBLESHOOTING
FAULT CAUSE SOLUTION
Water drips out
when moving unit
Unit was unplugged before
purging was complete.
Purge unit before moving. See “At the End of the Job,” p. 4.
Unit does not
operate
Unit not switched on.
No power to machine.
Switch unit on.
Plug in unit; check power cord connection at wall outlet and at
base of unit.
Blower wheel not
turning
Obstructed blower.
Remove duct ring and grill and remove obstruction. Replace
duct ring and grill.
Unit operating,
but room not dry
Not enough time to dry.
Poor air movement in room.
Excessive moist air infiltration.
Allow more time for drying.
Increase air movement with air movers.
Seal off area to reduce infiltration.
Unit collects too
little water
Room air is dry.
Room temperature is too low.
HAF filter is full.
Heat exchange block and/or
coils are clogged.
Confirm humidity level with hygrometer.
Increase room temperature.
Check filter. Clean or replace as necessary.
Check heat exchange block and coils. Clean as necessary.
If the problem you are experiencing is not listed here, call your local distributor or contact
our Service Department toll-free at 800-932-3030 for further assistance.
SPECIFICATIONS
Model LGR 7000XLi (F412)
Weight 107 lbs. | 49 kg
Dimensions
(H × D × W)
33.5 × 20 × 20 in. | 85 × 51 × 51 cm
Power 8.3 amps, 115V
Water removal AHAM
(80°F/60% RH)
130 pts. | 61.5 liters / day
Water removal low grain
(80°F/20% RH)
17 pts. | 8 liters / day
Process air (max.) 325 CFM* ductable floor-level outlet.
Noise level (avg.)
62 dB
Air filter
3M™ HAF filter
Part no. F368 (24 pack)
Drain hose
40 ft. | 12.2 m
Power cord 25 ft. | 7.6 m
Construction
Rotomolded shell
Safety
ETL certified CSA 22.2 no. 92
Specifications are subject to change without notice. Some values
may be approximate.
*Fan speed varies automatically for optimized performance.
Warranty information is available at www.dri-eaz.com.
Be sure to visit warranty.drieaz.com and register your
purchase. Your registration will help us provide you with
updated product information as needed.
For proper disposal, this unit should be taken to a
recycler licensed to process refrigeration equipment.
07-01776F 2015-02 F412 (115V) Warranty 07-00420 20 Dri-Eaz Products, Inc.