4. Operating Procedures
4.1 Connecting inverter to motor
If the inverter output terminal U, V and W are connected to the motor terminals U, V and W and the
motor is operated in the forward direction, it rotates clockwise viewed from t he position opposite to
the transmission side.
* OPERATION *
DIR/STOP/FOR/JOG
(0.0) FOUT
5.0 [Hz]
(2) Jogging
Press the JOG key. The motor rotates at the set frequency
(5Hz) while the JOG key is being pressed.
Select the forward or reverse direction with the FOR or
REV key.
4.3 Operation from Console
Press the OPR key to select the operation mode.
Press the DIR key.
(1) Normal operation
Press the START key. Make sure that the motor rotates in
the forward direction at the set frequency (25Hz). Then,
press the STOP key. The motor is decelerated and then
stops.
* OPERATION *
DIR/STOP/FOR
(0.0) FOUT
5.0 [Hz]
Display on console
Code # Functions Set items (Ex.)
00 Ref(Set).F 25Hz
05 Top.F 60Hz*
06 PC-Base.F 60Hz
07 Rated out V 200V
13 V/F.Pattern Liner
14 Start.Mode Min.F start
15 Stop.Mode Decel stop
4.2 Inputting Basic Data
The values indicated on the name plate of the motor have
been set in automatic measuring described in 3.1 above.
Set the values shown on the right according to the opera-
tion method. (Also set other items according to necessity)
(1) Press the FUNC key.
(2) Change code numbers displayed on the console with
the up and down arrow keys, and set the items
shown on the right one by one.
(3) Select the set frequency (Fref) on the monitor.
Press the MONI key, and code (00) Fout is
selected. Increase the code number to (01) with the
Up key to select (01) Fref.
Basic data setting
* Setting for 05 Top.F should be equal
to or greater than those for 06 PC-
Base.F.