7.4 PRELUBE
The Prelube cycle is a pre-lubrication cycle that is triggered when the system is powered on or reset. If the pre-lube cycle
value is set to 1 or greater the VIP5 will perform the set number of Lubrication Phases.
Note that if Each Lubrication Phase comprises two or more Lubrication Cycles, then the total cycles performed will be
equal to the Lubrication Cycles multiplied by the Prelube Cycles.
PRELUBE
1
YES
RUN n
LUBE Cycle
NO
NORMAL
OPERATION
POWER ON
OR RESET

Related product manuals