Appendix 3 Technical data
In the following table you can find the technical data.
Type 7kW 12kW 16kW
Type of gas G20 G31 G20 G31 G20 G31
Burner pressure mbar 13.4 26 17.9 28.9 18.7 29
Nom. load (Hs) kW 8.4 8.3 14.3 13.9 19.6 18.8
Nom. load (Hi) kW 7.6 7.6 12.9 12.8 17.6 17.4
Nom. output kW 7 7 12 11.8 16 15.7
Consumption L/h 785 305 1360 517 1875 704
Burner injector mm 2.25 1.55 2.7 1.9 3.15 2.25
Efficiency class 1 1 1 1 1 1
Appendix 4 Parts
Parts can be ordered through www.drugasar.co.uk
POWER FLUE
K7 230 - 240 Vac 50 Hz Rated power 140 W IP 20
K12 230 - 240 Vac 50 Hz Rated power 140 W IP 20
K16 230 - 240 Vac 50 Hz Rated power 155 W IP 20