3. Safety
3.1 General
Caution - Carefully read this chapter on safety,
before you start performing installation
or maintenance work;
- Please observe the general regulations and
the precautions/safety instructions in this
manual.
3.2 Regulations
Please install the appliance, including the electrical
installation, in accordance with the applicable national,
local and constructional (installation) regulations.
These are included in, for instance:
- Gas Safety (Installation and Use) Regulations;
- B.S. 6891;
- B.S. 5871: Part 1;
- B.S. 5440: Part 1;
- B.S. 5440: Part 2;
- Local Building Regulations;
- I.E.E Wiring Regulations;
- Health and Safety at work
3.3 Precautions / safety instructions during
installation
Carefully observe the following precautions/safety
regulations:
you should only install and maintain the appliance if you
are a competent installer in the field of gas heating:
do not make any changes to the appliance;
only use the flue gas discharge / combustion air supply
material supplied by Drugasar;
always place the appliance against a wall of incombustible
and heat-resistant material;
use the wall brackets when mounting the appliance to the
wall. This will guarantee the minimum required distance
of 10 mm from the back wall;
make sure the appliance has sufficient distance from
other objects and materials (see fig. 1). The free space
surrounding the appliance is necessary for a proper
and safe operation and for accessibility in case of
maintenance;
make sure there is a free outflow of warm convection air
at the front of the appliance;
make sure there is a free supply of cold convection air at
both sides of the appliance; Curtains, for example, could
block the inlet as a result of the sucking action of the
convection fan.
avoid warm convection air from recirculation through the
cold convection air inlet;
do not cover the appliance and the discharge material
and/or do not wrap it in an insulation blanket or any
other material;
avoid dirt in gas tubes and connections;
check the connections for gastightness before using the
appliance;
do not place and/or use the appliance in a moist
environment;
place an all-pole switch near the appliance, with a contact
opening of at least 3 mm;
connect the appliance to earth;
place electrical connections in such a way that they are
free from the appliance;
do not ignite the appliance until it is fully installed.
4. Removing the packaging
Note the following items when removing the packaging:
• Check the appliance for damages during transport.
• If necessary, contact Drugasar Service.
Check whether all parts have been supplied.
In Appendix 1 you can see which parts you should have
after removing the packaging.
Contact Drugasar Service if you do not have all the parts
after you finished removing the packaging.
• Dispose packaging in accordance with local regulations.
Kamara