INSTRUCTIONS FOR INSTALLATION
17
9.2.10 NTC temperature sensor
The temperature sensor is located in the convection air
inlet, at the filter on the right side of the appliance.
Take out the 2 screws on the control panel.
Lift the control panel and slide it slightly to the side.
Disconnect the wires of the temperature sensor on the
thermostat.
Remove the temperature sensor.
Place the new temperature sensor in reverse order.
9.2.11 Air pressure switch
Take out the screws.
!Tip You can reach the screws through the
convection air inlet on the right side
Disconnect the hoses.
Disconnect the wiring.
!Caution - Remember how the hoses are connected;
- Remember how the wiring is connected;
- The setpoint of the air pressure switch
depends on the type of appliance.
Remove the air pressure switch.
Place the new air pressure switch in reverse order.
10. Delivery
You must explain the user how to operate the appliance.
You should instruct the user on using the appliance for
the first time, its operation and annual maintenance.
Caution - Tell the user to close the gas tap
immediately and switch off the all-pole
switch in case of malfunctions/bad
performance and contact the installer in
order to prevent dangerous situations;
- Indicate the location of the gas tap;
- Indicate the location of the all-pole switch.
Instruct the user on how the appliance works.
Remind the user that the appliance requires annual
maintenance.
Give the user manual and installation manual to the user
(the installation manual should be kept near the appliance).
!