EasyManua.ls Logo

DSC HS2128 - Page 235

DSC HS2128
261 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix 4: Regulatory Approvals
Exit Time and Progress
Annunciation/Disable or
Remote Arming
[861]>[001]-[005], option
4
System times and audible exit beeps can be disabled when using the wireless key
to stay arm the system. When away arming, audible exit beeps can not be
disabled.
Default:
Enabled
Allowed
Entry delay(s)
[005]>[001]-[008], options
1 and 2
Access to entry and exit delays and bell time out for the system
Note: Combined entry delay and communications delay (abort window) shall not
exceed 60s.
Range: 30 sec.
to 4 min.
Default: 30
sec.
Required
(programmable)
Abort Window for Non-
Fire zones
[002]>[001]-[128], option
7 ON
Access to zone attributes, i.e., swinger shutdown, transmission delay and cross
zone. May be disabled by zone or zone type.
Default:
Enabled
Required
Abort Window Time - for
Non-Fire zones
[377]>[002], option 1
Access to the programmable delay before communicating alarms
Note: Combined entry delay and communications delay (abort window) shall not
exceed 60 seconds.
Range: 00 - 45
sec.
Default: 30
sees
Required
(programmable)
Abort Annunciation An audible tone is generated when an alarm is aborted during the abort window.
Hard-coded
ON
Required
Duress Feature
[*][5]> master code> user
2-95> 5> 2
When this feature is enabled, selected user codes send a duress reporting code
to the central station when used to perform any function on the system. Section
[019], option [6] must be enabled.
Default: N Required
Cancel Window
[377]>[002], option 6
Access to the communications cancel window. Minimum duration must be 5
minutes.
Range: 005-
255
Default: 005
Cancel Annunciation
[308]>[001], option 8
Access to the reporting code for Alarm Canceled.
A Cancel was
transmitted
Default:
Enabled
Required
Cross Zoning
[042]>Selection 3, option
002
Enables cross zoning for entire system. Zones can be enabled for cross zoning
via zone attribute option 8 in sections [002][101] - [128].
Programming
required
Default:
Disabled
Required
Burglary Verification
Timer
[005]>[000], option 3
Access to the programmable Cross Zone timer.
Range: 000-
255 sec.
Default: 60
seconds
Allowed
Swinger Shutdown for
Alarms
[377]>[001], option 1
Access to the swinger shutdown limit for zone alarms
For all non-fire zones, shut down at 1 to 6 trips.
Default: 2 trips
Required
(programmable)
- 235 -

Table of Contents

Related product manuals