Section 1: Introduction
1.1 About the System
The PowerSeries Neo alarm panel is a feature-rich, scalable alarm system designed for residential and light commercial
use. The alarm panel supports both hardwired and wireless devices. This section lists the features of the alarm panel, avail-
able models, and compatible devices.
The following symbols are used to indicate features or methods of operation that are only available in a particular market. No
symbol indicates the feature or operation is available for all markets unless noted specifically otherwise.
CP-01
- North America
EN
- Europe
NFA2P
- France
UK
- United Kingdom
1.1.1 Features
The following features are available on the PowerSeries Neo alarm controller.
Zones, Wireless Keypads, Wireless Keys, Panic Pendants and Proximity Tags
l 16, 32, 64, or 128 wireless or hardwired zones supported, including 6 or 8 hardwired zones available on the con-
troller.
l 40 zone types and 14 programmable zone attributes
l Up to 16 separate wireless keypads supported
l Up to 32 separate wireless keys or supported
l Up to 999 separate proximity tags supported
Access Codes
l Up to 1002 access codes: 1000 (level 2-EN) including one system master code (level 3-EN). In addition, one installer
code (level 3-EN), and one maintenance code are available.
Note: EN50131-1 compliant systems using 1000 access codes shall set the access code to 8 digits (section [041],
option 02).
l Programmable attributes for each user code (see "Access Code Attributes" on page 53)
Programmable Outputs (PGMs)
l Up to 4 programmable outputs (PGM) on the alarm controller with 49 available options
l 22, 38, 80, 148 maximum programmable outputs
System Supervision Features
The PowerSeries Neo continuously monitors a number of possible trouble conditions and provides audible and visual indic-
ation at the keypad. Trouble conditions include:
l AC power failure
l Zone trouble
l Fire trouble
l Telephone line trouble
l Communicator trouble
l Low battery condition