EasyManua.ls Logo

DSC HS2128 - Appendix 7: Specifications; Zone Configuration; Access Codes; Power Supply - North America

DSC HS2128
261 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix 7: Specifications
Zone Configuration
l 16, 32, 64, or 128 wireless zones supported and up to 8 hardwired zones available on the controller
l 40 zone types and 14 programmable zone attributes
l Zone configurations available: normally closed, single EOL and DEOL supervised
l Hardwired zone expansion (fully supervised) available using the model HSM2108 (eight zone expander module)
l Wireless zone expansion (fully supervised) available using the HSM2Host 2-way wireless integration module (oper-
ating at 915MHz (North America), 433MHz (Europe) and 868MHz (international)
Access Codes
l Up to 1002 access codes: 1000 (level 2-EN), one installer code (level 3-EN), and one maintenance code
l Programmable attributes for each user code (see "Access Code Attributes" on page 53)
l When using 8-digit access codes, the minimum number of variations are:
HS2016-4: 2083333
HS2032: 1388888
HS2064/HS2128: 1052631
HS2064 E: 200000
HS2128 E: 100000
Warning Device Output
l Integral sounder capable of 85 dB @ 3m, self-powered type Z
l 2 remote, wireless indoor/outdoor warning devices supported: models PGX901 (indoor), PGX911 (outdoor) (X=4, 8,
or 9)
l Programmable as steady, pulsed or temporal three (as per ISO8201) and temporal four (CO alarm) output
l Warning device sounds alarms in the following priority: fire, CO, burg
Memory
l CMOS EEPROM memory
l Retains programming and system status on AC or battery failure for 20 years min. (not verified by UL)
Power Supply - North America
Transformer: DSC PTD1640U, PTD1640
Primary: 120V, 60Hz Class II
Secondary: 16.5VAC, 40VA Max.
Power Supply - International
l Input ratings: 220V-240Vac, 50/60Hz, 200mA
l Transformer required, mounted in the same enclosure, permanently connected
l Transformer secondary ratings: 16.5Vac, 40VA min.
Note: For installations using the transformer mounted inside the cabinet, replace fuse only with the same type (20mm) rated
250V/315mA.
Regulated power supply:
l 1.7A regulated, supervised and integral to the control unit
l Type A as per EN50131-6 Standard
l 700mA auxiliary supply, 12V DC
l Positive temperature coefficient (PTC) for Bell, Aux+ and Battery terminals
l Reverse battery detection/protection
l Supervision for AC power and low battery

Table of Contents

Related product manuals