Appendix 7: Specifications
l Normal and high current battery charge options
l Supervised battery charging circuit
Current draw (panel):
l 85mA (nominal) 2A(Max)
Bell Output:
l 12V, 700mA supervised (1k Ohm) bell output (current limited at 2 amps)
l Steady, Pulsed, Temporal 3 fire, Temporal 4 CO alarm cadences
l Bell short detection (software + hardware)
Aux+:
l Voltage range = 9.6V - 13.8V DC
l Current = 700mA (shared with Corbus R(ed))
l Output ripple voltage: 270mVp-p max.
l Onboard programmable outputs:
l PGM 1 - 50mA switched programmable output
l PGM 2 - 300mA current-limited switched programmable output. 2-Wire smoke detectors (90mA current lim-
ited) are supported using this PGM
l PGM 3 - 50mA switched programmable output
l PGM 4 - 50mA switched programmable output
l Hardware PGM over current protection
Battery
l 12V sealed lead acid, rechargeable
l Battery capacity:
l 4 hours (UL commercial burglary/residential burglary),
l 12 hours (EN50131),
l 24 hours (UL/ULC resi fire, ULC com burglary, ULC com fire monitoring - no bell load allowed); INCERT [Bel-
gium])
Note: For T 014 compliance (INCERT certification), only 14Ah (2x7Ah) batteries were tested and are accepted for
INCERT certified systems.
l Maximum standby time: 24 hours (with 14Ah battery and Aux current limited to 470mA)
l Recharging time to 80% 72 hours
l Recharging rate: 240mA (12 hours max.), 480mA (24 hour backup)
l Backup time: 24 hours (UL)
l Battery lifespan: 3-5 years
l Low battery trouble indication threshold 11.5VDC
l Battery restore voltage 12.5V
l Main board current draw (battery only):
l HS2016-4/32/64/128 (no alternate communicator) standby 85mA DC
l HS2016-4/32/64/128, (including alternate communicator) standby 190mA DC
l Transmit (alternate communicator module) 195mA DC
l Resettable fuses (PTC) used on circuit board
l Supervision for loss of primary power source (AC fail), battery loss or battery low voltage (battery trouble) with indic-
ation provided on the keypad
l Internal clock locked to AC power frequency
Operating Environmental Conditions
- 247 -