Section 6: Programming
[001] – Installer Code
This code is used by the installer to gain access to Installer Programming [*][8]. Users with this access code have access to
all levels of system programming.
EN
Note: For EN50131-1 approved installations the installer code cannot change the master code or any other level 3 codes.
[002] – Master Code
This code is used by the master user, a person designated to perform operational tasks beyond those of the standard user.
The master code provides access to functionality in the [*][5] and [*][6] menus.
[003] – Maintenance Code
This code is usually assigned temporarily to maintenance personnel who must deactivate the alarm to enter the premises.
The maintenance code can arm and disarm the system, but does not grant access to any other functionality.
6.3.5 [007] - [008] PGM Configuration
This section describes how to set up and configure programmable outputs.
PGMs are used to send electrical current to external devices such as lights and sirens, usually when an alarm event occurs.
The alarm controller provides up to three 50mA PGMs and one 300mA PGM. PGM outputs can be expanded using the
optional 8-output expander (HSM2208) and the 4 high-current output expander (HSM2204).
Programming an output is a four-step process:
1. Program the PGM
2. Assign the PGM to a partition.
3. Assign an output attribute.
4. Assign an output option.
See "[011] PGM Configuration Options" on page 95 for PGM slot alignment.
[007] PGM Programming
This is the base menu used by the installer to assign PGMs to the main bell and a partition.
[000] Main Bell Partition Assignment
This programming section is used to define which partitions activate the main bell when they go into alarm. All partitions are
selected by default.
[001]-[164] PGM Partition Assignment
This option enables the installer to assign each PGM output to a partition. To assign a PGM to a partition, first select the PGM
output (PGM 001-164), then select the partition (1-8).
Note: This field is only supported by PGM types that have multiple partition capabilities (e.g., command outputs, away arm-
ing). It does not affect system outputs (e.g., ground start pulse).
[008] PGM Timer Programming
[000] PGM Minutes/Seconds
This option determines if the timer is in minutes or seconds.
[001]-[164] PGM Timer
This timer programs the duration (in seconds or minutes) that PGMs 1-164 activate if programmed to follow the PGM Timer.
Select option 001-164 for PGM 1-164.
This option does not affect outputs programmed as Sensor Reset.
- 79 -