EasyManua.ls Logo

DSC HS2128 - Page 85

DSC HS2128
261 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 6: Programming
175 Bell Status and Programming Access Output
This PGM activates when the siren, Installer Programming mode or DLS/SA is active. It deactivates after bell timeout, when
Installer Programming is exited or when DLS/SA programming is disconnected.
176 Remote Operation
This output is activated and deactivated remotely on command from DLS software.
Note: Not for use with UL/ULC listed installations.
184 Open After Alarm
This output activates when the system has been disarmed after an alarm. It deactivates when a valid user code is entered or
when the PGM Output timer expires.
200 Zone Follower - PGM By Zone
This option allows the PGM to activate when the assigned zone is opened and deactivate when the zone is restored or, if pro-
grammed, when a valid access code is entered. This PGM follows the state of the assigned zone, regardless of the partition
the zone or PGM is assigned to.
To program which zone the PGM will follow, see "[011] PGM Configuration Options" on page 95.
201-216 Zone Follower (Zones 1-128)
This output type is assigned to a group of zones and is normally activated, but deactivates when a zone is tripped. Zones are
assigned to this output in the following groups:
201 Zones 1-8 209 Zones 65-72
202 Zones 9-16 210 Zones 73-80
203 Zones 17-24 211 Zones 81-88
204 Zones 25-32 212 Zones 89-96
205 Zones 33-40 213 Zones 97-104
206 Zones 41-48 214 Zones 105-112
207 Zones 49-56 215 Zones 113-120
208 Zones 57-64 216 Zones 121-128
If multiple zones are enabled, any active zone in that group triggers the output. The PGM will not activate again until all
zones are restored.
6.3.7 [010] PGM Attributes
The following options are used to program the operating characteristics of the main bell and PGM outputs.
[000] Main Bell Mask
This programming section is used to configure the types of audible alarms that trigger the main bell output on the alarm con-
troller. All options are selected by default.
Fire Alarm
ON: Fire alarm ([F] key, Fire zones) activates the main siren.
OFF: Fire alarm does not activate the main siren.
CO Alarm
ON: CO alarm activates the main siren.
OFF: CO alarm does not activate the main siren.
- 85 -

Table of Contents

Related product manuals