27
PC3000 Version 7.51
[17] Zone Definitions for Zones 9 to 16 Page 17
Note: Zones 9-16 cannot be programmed for fast response - Do not use fast response devices on these zones.
e.g. Vibration detectors.
Default
1st Digit 2nd Digit
0 1 Zone 9 0 = Slow, audible 0 = Delay
0 1
Zone 10 1 = Slow, silent 1 = Instant
0 1
Zone 11 2 = Interior
0 1
Zone 12 3 = Interior...Home-Away
0 1
Zone 13 4 = 24 hr...Bell
0 1
Zone 14 5 = 24 hr...Bell/Buzzer
0 1
Zone 15 6 = 24 hr...Buzzer
0 1
Zone 16 7 = Double delay
8 = 4x Delay
9 = Day
A = Delay...Home-Away
[18] 1st System Option Code Page 18
Default Zone Light On Zone Light Off
Off Zone Light 1 ........................ Communication disabled Communication enabled
Off
Zone Light 2 ........................ Restorals on bell timeout Restorals on disarming
Off
Zone Light 3 ........................ Alarm display while armed No alarm display/armed
Off
Zone Light 4 ........................ DTMF dialing Pulse dialing
Off
Zone Light 5 ........................ N/C zones EOL resistors zones
Off
Zone Light 6 ........................ Keypad [P]anic audible Silent
On
Zone Light 7 ........................ Call 1st phone only Back up to 2nd phone
Off
Zone Light 8 ........................ 16th code = maid's code Normal code
[19] 2nd System Option Code Page 18
Default Zone Light On Zone Light Off
Off Zone Light 1 ........................ Bell pulses always Bell pulses upon fire only
Off
Zone Light 2 ........................ Master code not changeable Master code changeable
Off
Zone Light 3 ........................ Bell squawk enabled Bell squawk disabled
Off
Zone Light 4 ........................ PC16 OUT enabled PC16 OUT disabled
Off
Zone Light 5 ........................ TLM trouble only TLM audible when armed
Off
Zone Light 6 ........................ 1400Hz Radionics 2300Hz Radionics
Off
Zone Light 7 ........................ TLM disabled TLM enabled
Off
Zone Light 8 ........................ Access code req'd for bypass Access code not req'd