28
PC3000 Version 7.51
[20] Zones 1 to 8 Bypass Mask Page 18
Default
On Zone Light 1
On
Zone Light 2
On
Zone Light 3
On
Zone Light 4
On
Zone Light 5
On
Zone Light 6
On
Zone Light 7
On
Zone Light 8
[21] Zones 9 to 16 Bypass Mask Page 18
Default
On Zone Light 1
On
Zone Light 2
On
Zone Light 3
On
Zone Light 4
On
Zone Light 5
On
Zone Light 6
On
Zone Light 7
On
Zone Light 8
[22] System Times Page 18
Default
3 0 Entry Delay Time (in seconds)
4 5
Exit Delay Time (in seconds)
0 4
Bell Cut-off Time (in minutes)
3 0
AC Failure Transmission Delay (in minutes)
5 0
Normal Zone Response Time (x 10 ms)
3 0
Test Transmission Cycle Time (in days)
[23] System Clock Times Page 19
Default
9 9 9 9 Automatic Arming Time of Day
9 9 9 9
For Future Use
9 9 9 9
Test Transmission Time of Day
[24] New Installer’s Code Page 19
Default
3 0 0 0 Enter 4 digits from 0 to 9.
Do not enter [Q] or [#].
Note:
If zone light is on, the zone can be
bypassed using the [Q] [1] command.
Note:
If zone light is on, the zone can be
bypassed using the [Q] [1] command.
Notes:
1.Valid entries are: 01 to 99.
2.Do not enter “00” - it is not a valid
entry.
Enter 4 digits: 00 to 23 hr, 00 to 59 min.
If not used, leave at the factory default
settings.