39
P R O G R A M M I N G W O R K S H E E T S
International Programming
[700] Clock Adjust (Section 5.28 “Clock Adjust”)
Default: 60 I_______I_______I (Valid entries are 01-99 seconds)
[701] First International Options Code
Default Option ON OFF Section
OFF
I_______I 1 50 Hz AC 60 Hz AC 2.2
OFF
I_______I 2 Time Base is Internal Crystal Time Base is AC Line 5.29
OFF
I_______I 3 AC/DC Arming Inhibit enabled AC/DC Arming Inhibit disabled 5.17
OFF
I_______I 4
All System Tampers Require Installer Reset
All System Tampers follow Restore 5.25
OFF
I_______I 5 6-Digit User Access Codes 4-Digit User Access Codes 5.1
OFF
I_______I 6 Busy tone detection enabled Busy tone detection disabled 5.5
OFF
I_______I 7 High Current Battery Charge Standard Current Battery Charge 2.2
OFF I_______I 8 For Future Use
[702] Second International Options Code
Default Option ON OFF Section
OFF
I_______I 1 Pulse Dialing Make/Break Ratio is 33/67 Pulse Dialing Make/Break Ratio is 40/60 5.5
ON
I_______I 2 Force Dialing enabled Force Dialing disabled 5.5
OFF
I_______I 3 Land line Test Transmission in minutes Land line Test Transmission in days 5.14
OFF
I_______I 4 1600 Hz Handshake Standard Handshake 5.9
OFF
I_______I 5 ID Tone enabled ID Tone disabled 5.5
OFF
I_______I 6 2100 HZ ID Tone 1300 Hz ID Tone 5.5
OFF
I_______I 7
One Time 1-Hr User enabled DLS Window
Full 6-Hr User enabled DLS Window 5.10
OFF
I_______I 8 Bell on FTC when armed FTC Trouble only when armed 5.5
[703] Delay Between Dialing Attempts
(Section 5.5 “Communicator - Dialing”)
Default: 000 I______ _ __I___ _ _ ___I__ _ _ ____I (Valid entries are 000-255 Seconds)
Module Programming
[801] PC5400 Printer Module Programming
Please refer to your PC5400 Installation Manual for installation and programming instructions.
[803] LINKS2X50 Long Range Radio Interface Programming
Please refer to your LINKS2150 Installation Manual for installation and programming instructions.
[804] PC5132 Wireless Expansion Programming
Please refer to your PC5132 Installation Manual for programming locations and instructions.
Special Installer Functions
[901] Installer Walk Test Mode Enable / Disable (Section 5.32 “Walk Test [Installer]”)
[902] Module Supervision Reset (Section 2.7 “Removing Modules”)
[903] Module Supervision Field (Section 2.6 “Supervision”)
[904] Wireless Module Placement Test
For more information, please refer to your PC5132 Installation Manual
• Select the module / transmitter (Zones 01-8).
• Press [#] to Cancel.
Placement Led Keypad LCD Keypad Bell / Buzzer
Good Light 1 ON Steady “GOOD” 1 Beep / Squawk
Fair Light 2 ON Steady “FAIR” 2 Beeps / Squawks
Bad Light 3 ON Steady “BAD” 3 Beeps / Squawks
[990] Installer Lockout Enable
(Section 5.31 Installer Lockout”)
[991] Installer Lockout Disable (Section 5.31 “Installer Lockout”)
[993] Restore LINKS2X50 Factory Default Programming (Section 5.30 “Resetting Factory Defaults”)
[996] Restore PC5132 Factory Default Programming (Section 5.30 “Resetting Factory Defaults”)
[997] Restore PC5400 Factory Default Programming (Section 5.30 “Resetting Factory Defaults”)
[999] Restore PC585 Factory Default Programming (Section 5.30 “Resetting Factory Defaults”)