28
P R O G R A M M I N G W O R K S H E E T S
Keypad Programming
[000] Keypad Enrollment
(Section 2.5 “Keypad Enrollment”)
NOTE: This must be done at each keypad requiring programming.
[0] Slot [Valid entries are 11-18; ie. enter [11] for slot 1, [12] for slot 2, etc.]
[1] Function Key 1 Assignment (Valid entries are 00-17)
[2] Function Key 2 Assignment (Valid entries are 00-17)
[3] Function Key 3 Assignment (Valid entries are 00-17)
[4] Function Key 4 Assignment (Valid entries are 00-17)
[5] Function Key 5 Assignment (Valid entries are 00-17)
Function Key Options:
00 Null Key
03 Stay Arm
04 Away Arm
05 [
][9] No-Entry Arm
06 [
][4] Chime On / Off
07 [][6][——][4] System Test
08 [
][1] Bypass Mode
09 [
][2] Trouble Display
10 [
][3] Alarm Memory
11 [
][5] User Programming
Slot (Address) Function Function Function Function Function
Key 1 Key 2 Key 3 Key 4 Key 5
LED Defaults 11 03 04 06 14 16
LCD Defaults 18 03 04 06 14 16
KEYPAD 1
I________I________I I________I I________I I________I I________I I________I
KEYPAD 2 I________I________I I________I I________I I________I I________I I________I
KEYPAD 3 I________I________I I________I I________I I________I I________I I________I
KEYPAD 4 I________I________I I________I I________I I________I I________I I________I
KEYPAD 5 I________I________I I________I I________I I________I I________I I________I
KEYPAD 6 I________I________I I________I I________I I________I I________I I________I
KEYPAD 7 I________I________I I________I I________I I________I I________I I________I
KEYPAD 8 I________I________I I________I I________I I________I I________I I________I
Basic Programming
Zone Definitions
00 Null Zone (Not Used) 09 24 Hour Supervisory 18 24 Hour Sprinkler
01 Delay 1 10 24 Hour Supervisory Buzzer 19 24 Hour Water
02 Delay 2 11 24 Hour Burglary 20 24 Hour Freeze
03 Instant 12 24 Hour Holdup 21 24 Hour Latching Tamper
04 Interior 13 24 Hour Gas 22 Momentary Keyswitch Arm
05 Interior, Stay/Away 14 24 Hour Heat 23 Maintained Keyswitch Arm
06 Delay, Stay/Away 15 24 Hour Medical 24 LINKS Answer
07
Delayed 24 Hour Fire (Hardwired)
16 24 Hour Panic 25 Interior Delay
08
Standard 24 Hour Fire (Hardwired)
17 24 Hour Emergency 87 Delay 24 Hour Fire (Wireless)
88 Standard 24 Hour Fire (Wireless)
If 24-hour Buzzer zones are used, keypads must be installed
[001] Zone 1-8 Definitions
(Section 5.2 “Zone Programming”)
Default Default
01 I_______I_______I Zone 1 00 I_______I_______I Zone 5
03 I_______I_______I Zone 2 00 I_______I_______I Zone 6
04
I_______I_______I Zone 3 00 I_______I_______I Zone 7
04 I_______I_______I Zone 4 00 I_______I_______I Zone 8
Keypad zones are assigned in Section [020]. Zone Attributes are assigned in Sections [101] - [108].
Zone assignment is in section [202].
12 [][6] User Functions
13 Command Output #1 [
][7][1]
14 Command Output #2 [
][7][2]
16 [
][0] Quick Exit
17 [
][1] Reactivate Stay/Away’s