29
P R O G R A M M I N G W O R K S H E E T S
[005] System Times
Default [001-255]
030 I_______I_______I_______I Entry Delay 1 (in seconds) (Section 5.18 “Entry/Exit Delay Options”)
045 I_______I_______I_______I Entry Delay 2 (in seconds) (Section 5.18 “Entry/Exit Delay Options”)
120 I_______I_______I_______I Exit Delay (in seconds) (Section 5.18 “Entry/Exit Delay Options”)
040 I_______I_______I_______I Bell Cut-off (in minutes) (Section 5.13 “Siren”)
[006] Installer’s Code
(Section 4.1 “Installer Programming”)
Default
0580 I_______I_______I_______I_______I
[007] Master Code
(Section 5.1 “Programming Security Codes”)
Default
1234 I_______I_______I_______I_______I
[008] Maintenance Code
(Section 5.1 “Programming Security Codes”)
Default
AAAA I_______I_______I_______I_______I
[009] PGM Output Programming (PGM 1 and 2)
(Section 5.11 “PGM Output Options”)
Programmable Output Options
01 Burglary and Fire Bell Output 13 Kissoff Output
02 For Future Use 14 Ground Start Pulse
03 Sensor Reset 15 Remote Operation (DLS-1 Support)
04 For Future Use 16 LINKS1000 Support (PGM1 only)
05 System Armed Status 17 Away Armed Status
06 Ready To Arm 18 Stay Armed Status
07 Keypad Buzzer Follow Mode 19 Command Output #1 ([✱] [7] [1])
08 Courtesy Pulse 20 Command Output #2 ([✱] [7] [2])
09 System Trouble Output (with Trouble options) 21-24 For Future Use
10 System Event [Strobe (with Event options)]
11 System Tamper (all sources: zones, kpd, modules)
12 TLM and Alarm
Output types [03] and [20] cannot be used together on the same system.
Default
19
I_______I_______I PGM 1
10 I_______I_______I PGM 2
Program PGM Option Attributes in sections [141] & [142].
[012] Keypad Lockout Options
(Section 5.21 “Keypad Lockout Options”)
If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.
Default
000
I_______I_______I_______I Number of Invalid Codes Before Lockout (001-255 codes)
000
I_______I_______I_______I Lockout Duration (001-255 minutes)
[013] First System Option Code
Default Option ON OFF Section
OFF
I________I 1 Normally Closed Loops End-of-Line Resistors 2.8
OFF
I________I 2 Double End-of-Line Resistors Single End-of-Line Resistors 2.8
ON
I________I 3* Panel shows all troubles when armed Panel shows only Fire troubles when armed 3.4
OFF
I________I 4 Tampers/Faults do not show as open Tampers/Faults show as open 3.4
OFF
I________I 5 For Future Use
ON
I________I 6 Audible Exit Fault Enabled Audible Exit Fault Disabled 5.18
ON
I________I 7
Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past shutdown 5.20
OFF I________I 8 Temporal Three Fire Signal Enabled Standard Pulsed Fire Signal 5.13
* Option 3 must be OFF if LCD keypads older than v2.0 are used.