42
Downloading Options
[401] First Downloading Option Code (Section 5.11 Downloading on page 20)
Default Option ON Off
OFF I_______I 1 Answering machine/double call enabledAnswering machine/double call disabled
ON
I_______I 2 User Can Enable DLS Window User Cannot Enable DLS Window
OFF
I_______I 3 Call-Back Enabled Call-Back Disabled
OFF I_______I 4 User-initiated Call-up Enabled User-initiated Call-up Disabled
OFF
I_______I 5-8 For future use
[402] Downloading Computer’s Telephone Number (32 Digits)
(Section 5.11 Downloading on page 20)
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
[403] Downloading Access Code (Section 5.11 Downloading on page 20)
Default: 1555 I_______I_______I_______I_______I Enter 4 Hex digits
[404] Panel Identification Code
(Section 5.11 Downloading on page 20)
Default: 1555 I_______I_______I_______I_______I Enter 4 Hex digits
[405] Answering Machine Double-call Timer
(Section 5.11 Downloading on page 20)
Default: 060 I_______I_______I_______I (Valid entries are 001-255 seconds)
[406] Number of Rings to Answer On
(Section 5.11 Downloading on page 20)
Default: 000 I_______I_______I_______I (Valid entries are 000-255 rings)
[490] GSM Preamble (Downloading Telephone Number)
(Section 5.11 Downloading on page 20)
Default: FFFF I_______I_______I_______I_______I (Program all unused digits with Hex F)
[499] [Installer’s Code] [499] Initiate PC-Link (Local Downloading)
(Section 5.11 Downloading on page 20)
International Programming
[700] Clock Adjust (Section 5.29 Clock Adjust on page 27)
Default: 60 I_______I_______I (Valid entries are 01-99 seconds)
[701] First International Options Code
Default Option ON Off Section Page #
OFF
I_______I 1 50 Hz AC 60 Hz AC 2.2 3
OFF
I_______I 2 Time Base is Internal Crystal Time Base is AC Line 5.30 27
OFF
I_______I 3 AC/DC Arming Inhibit enabled AC/DC Arming Inhibit disabled 5.18 24
OFF I_______I 4 All System Tampers Require Installer Reset All System Tampers follow Restore 5.26 26
OFF
I_______I 5 6-Digit User Access Codes 4-Digit User Access Codes 5.1 15
OFF
I_______I 6 Busy tone detection enabled Busy tone detection disabled 5.6 17
OFF I_______I 7 High Current Battery Charge Standard Current Battery Charge 2.2 3
OFF
I_______I 8 For future use
[702] Second International Options Code
Default Option ON Off Section Page #
OFF
I_______I 1 Pulse Dialing Make/Break Ratio is 33/67 Pulse Dialing Make/Break Ratio is 40/60 5.6 17
ON
I_______I 2 Force Dialing enabled Force Dialing disabled 5.6 17
OFF I_______I 3 Land line Test Transmission in minutes Land line Test Transmission in days 5.15 23
OFF
I_______I 4 1600 Hz Handshake Standard Handshake 5.10 19
OFF
I_______I 5 ID Tone enabled ID Tone disabled 5.6 17
OFF I_______I 6 2100 HZ ID Tone 1300 Hz ID Tone 5.6 17
OFF
I_______I 7 One Time 1-Hr User enabled DLS Window Full 6-Hr User enabled DLS Window 5.11 20
OFF
I_______I 8 Bell on FTC when armed FTC Trouble only when armed 5.6 17
[703] Delay Between Dialing Attempts
(Section 5.6 Communicator Dialing on page 17)
Default: 001 I_________I________I________I (Valid entries are 000-255 Seconds)