PowerSeries - PC1616/PC1832/PC1864
Openings & Closings
Zone Restorals
DLS/Installer Lead IN/OUT
Digit 5 selects DLS connection options.
Users CLOSINGS, Residential Dial Reporting codes Section
1-8 5152535455565758[339]
9-16 61 62 63 64 65 66 67 68 [339]
17-24 71 72 73 74 75 76 77 78 [340]
25-32 81 82 83 84 85 86 87 88 [340]
33-40 FF FF FF FF FF FF FF 98 [601]
Users OPENINGS, Residential Dial Reporting codes Section
1-8 1112131415161718[342]
9-16 21 22 23 24 25 26 27 28 [342]
17-24 31 32 33 34 35 36 37 38 [343]
25-32 41 42 43 44 45 46 47 48 [343]
33-40 FF FF FF FF FF FF FF 98 [605]
Enable Opening/Closings call directions for Phone 2 [367]
Zones Alarm Restoral Reporting Codes Section
1-64 00 00 00 00 00 00 00 00 [324]-[327]
00 = Disabled
Miscellaneous Maintenance Reporting Codes Section
DEF DEF DEF 00 00 DEF DEF DEF DEF DEF 00 00 [347]
DEF = No change to default values, 00 = Disabled
Option Programming Section DLS Connection/Call back setting
1 [401] Option 1 OFF
Option 3 OFF
[406] 0
Double Call Disabled, Call Back Disabled
Number of rings to answer on set to 0
2 [401] Option 1 ON
Option 3 OFF
[406] 9
Double Call Enabled, Call Back Disabled
Number of rings to answer on set to 9
3 [401] Option 1 ON
Option 3 ON
[406] 9
Double CallEenabled, Call Back Enabled
Number of rings to answer on set to 9