EasyManua.ls Logo

DSC PowerSeries PC1832

DSC PowerSeries PC1832
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix E: Template Programming
Digit 4 selects reporting code configurations
Common Group
Selected Troubles
Option
Common
Group
Selected
Troubles
Openings/
Closings
Zone
Restorals
DLS/Installer
Lead In/Out
1 
2 
3 
4 
5 
6 
7 
8
indicates included, Blank indicates default setting, indicates disabled
Description Phone 1 Phone 2 Sections
Set all Reporting Codes to automatic [320] - [349], [601] - [608] FF
Alarm/Restore call directions enabled [351][1] ON, [2] OFF
Tamper/Restore Call directions disabled [359][1] OFF, [2] OFF
Openimg/Closing Call directions disabled [367][1] OFF, [2] OFF
Maintenance Call Directions enabled [375][1] ON, [2] OFF
Test Transmission Call directions disabled [376][1] OFF, [2] OFF
Trouble [345] Alarms [346] Restoral
Battery FF FF
AC Failure 00 00
Bell Circuit FF FF
Fire, Alarm FF FF
Aux PS FF FF
TLM 00 FF
General System 00 00
General System Supervisory FF FF
FF = Communicate in automatic format , 00 = Disabled
WWW.DIYALARMFORUM.COM