3.3 Enroll & Program Wireless Keys
For wireless keys to work on the system, you need to enroll them and then program the
function buttons. Wireless keys are not assigned to zones and require no zone
programming. You can enroll up to 8 wireless keys on the system.
Enroll Wireless keys
1. At a system keypad, enter [✱][8][Installer’s code] to go to the Installer
Programming section.
2. Enter programming section [804].
3. Enter a 2-digit number [41]-[48] to assign the wireless key a slot. These numbers
correspond to wireless key numbers 01-08.
4. Enter the key’s ESN. The entry
must
be 6 digits. If an older key with a 5-digit ESN
is being enrolled, add the digit [0] to the beginning of the ESN. (E.g., if
ESN=61234, enter 061234)
5. The key is now enrolled on the system. Record the serial number and the assigned
slot number in the programming worksheets in the back of this manual.
6. Repeat steps 3 - 5 until all wireless keys have been enrolled.
7.
((
((
(
PC5020/PC5020/
PC5020/PC5020/
PC5020/
PC501PC501
PC501PC501
PC501
XX
XX
X
only) only)
only) only)
only) By default, all wireless keys are assigned to Partition 1.
To assign keys to Partitions 2 to 8, program the appropriate partition number in
section [69].
NOTE: A wireless key can only be assigned to one partition.
8. To exit press [#].
Program the Wireless Key Function Buttons
WS4939/WLS919-433 wireless keys have four programmable function buttons. By
default, all wireless key function buttons are set for 03, 04, 27, 30 (Stay Arm, Away Arm,
Disarm, Panic Alarm). The functions can be reprogrammed if desired. After the functions
are programmed, when you press and hold one of the buttons for two seconds, the system
will execute the programmed function.
For systems not using partitions: program the function buttons in section [61]. All
wireless keys will have the same four functions.
For systems using more than one partition (PC5020/PC501X only): All wireless keys
assigned to Partition 1 will have the four functions programmed in section [61]. Likewise, all
wireless keys assigned to Partition 2 will have the 4 functions programmed in section [62], and
all wireless keys assigned to Partition 8 will have the 4 functions programmed in section [68].
For example, if function button 1 in Section [61] is programmed for Stay arming, then pressing
the first button on wireless keys assigned to Partition 1 will Stay arm Partition 1.
NOTE: Wireless keys will not work when the partition they are assigned to is being
accessed for zone bypassing or programming.
1. At a system keypad, enter [✱][8][Installer’s code].
2. Enter programming section [804].
3. Enter programming section [61] to [68] for keys assigned to Partitions 1 to 8.
4. For each of the 4 function buttons, enter the 2-digit number of the function you
want to select. See the programming worksheets in the back of this manual for a
list of function key options.
5. Record your programming choices in the worksheets in the back of the manual.
6. To exit press [#].
W I R E L E S S D E V I C E S