[851][004] set to 0087h (135s heartbeat).
NOTE: The compatible receiver at ARC location shall have supervision window programmed for 1800s (ATS4) or 180s (ATS
5).
l
[851][005] options 1 and 3 shall be enabled
Testtransmission (required for ATS3):
l
[851] System test options [026] and [027] shall be enabled (FF) for the communication paths available.
l
[851][124] and [125] shall be programmed with time of day for test transmission and 1440 minutes (24h) for test trans-
mission cycle
Configuration of communication paths (all ATS classes)
l
[300][001] selectoption 02 for auto routing (this will allow transmission of the eventsover all available communication
paths in the system)
l
[380] enable option 5 (YES) for parallel transmission over all available communication paths (if redundant configuration is
desired)
l
[382] enable option 5 (YES) this will enable Alternate communicator
l
[384] enable the desired back-up configuration (receiver 2 back-up for receiver 1 or receiver 3 back-up for receiver 1).
Technical Specifications, Ratings and Compatibility
Table 1: Communicator Ratings
Model TL280(R)
Power Supply Ratings
Input Voltage
10.8-12.5 VDC.
Power is supplied from the panel’s PC- Link header or a PCL- 422
module in remote cabinet installations.In remote cabinet installations, the
PCL-422 module located with the communicator is powered by either an
HSM2204 or an HSM2300. Refer to the PCL-422 installation instructions
for details.
Current Consumption
Current 100mA @ 13.66V
Environmental Specifications
Operating Temperature -10°C to 55°C
Humidity 5% ~ 93% relative humidity,non-condensing
Mechanical Specifications
Board Dimensions (mm) 100 × 150 × 15
Weight (grams) with bracket 290
Table 2: Compatible Receivers and Panels
Communicator Receiver/Panel Description
3G2080(R) Receiver
l Sur-Gard System I-IP Receiver, version 1.13+
l Sur-Gard System II Receiver, version 2.10+
l Sur-Gard SG-DRL3-IP, version 2.30+ (for Sur-Gard System III Receiver)
l Sur-Gard SG-DRL4-IP version 1.20+ (for Sur-Gard System IV Receiver)
l Sur-Gard SG-DRL5-IP version 1.00+ (for Sur-Gard System 5 Receiver)
TL2803G(R) Panel
l HS2016
l HS2032
l HS2064
l HS2128
NOTE: Enter [*][8][Installer Code][900] at keypad to view the panel version number.
Pre Installation Configuration
Encryption
The communicator uses 128 Bit AES encryption. Encryption can only be enabled from the monitoring station receiver. Each
receiver (Ethernet 1 and 2) can independently have encryption enabled or disabled. When encryption is enabled, the central
station will configure the device to encrypt communications the next time the communicator module performs a communication
to that receiver.
NOTE: Packets will start being encrypted only after the nextevent is sent to that receiver, or if the unit is restarted.