6. ACTIVATOR MANAGEMENT
LEARN AN ACTIVATOR
1. Enter in programming menu (jumper SETUP closed) and select Learn. Activator
2. Select the memory position using the EDIT button (hold down the button to increase quickly the memory position):
3. After some seconds, beside to the radio zone number appears the _listening symbol: the receiver is waiting for a radio code from
remote control.
If appears the Xsymbol after the radio zone number, it means that the memory position is already used. It is possible to overwrite or
delete it (see next paragraph)
4. Press any button on remote control
5. When the radio code is received, on receiver display appears the blinking Xsymbol (instead _”): the receiver is processing the code.
If it is a valid code the remote control is stored, the Xsymbol stays solid:
The remote control is not stored if:
the radio code is already stored in other memory position
it is not a valid radio code (example: it a sensor radio code…)
In case of error, some “beep” are emitted and the receiver wait for another radio code.
6. To learn other remote controls, press the EDIT button to switch to another free memory position and repeat the previous steps.
It is possible to store up to 9 remote controls.
7. At the end of learning, switch to next function by pressing the MENU button or exit from programming opening the jumper SETUP.
DELETE AN ACTIVATOR
To delete an activator, select it and hold down the MENU button for at least 5 seconds:
Learn. Activator
Remote 01
Learn. Activator
Remote 04
Learn. Activator
Remote 04 _
Learn. Activator
Remote 04 X
Learn. Activator
Remote 04 X