14
7. ARMING AND DISARMING
It is possible to arm (activate) the receiver and the connected control panel, in two ways:
1. With remote controls: the receiver must be programmed in MASTER mode, the control panel must be connected to the output COM-
NC-NA. It is possible to arm the receiver in TOTAL and PARTIAL mode
2. With wired bi-stable input RST: the receiver must be programmed in SLAVE mode and the input RST must be connected to the wired
status output of the control panel:
+12 V: TOTAL arming
no +12 V: DISARMED
It is possible to arm the receiver only in TOTAL mode
TOTAL ARMING
Press once the arming button (TOTAL) of a remote control.
The receiver emits a “beep” (if the “Beep Arming” function is enabled) to confirm the code is received.
On display appears:
PARTIAL ARMING
Press twice the arming button or once the partial arming button (if available) on a TXS4 remote control.
The receiver emits a “beep” each time it receives the arming button code as confirm.
On display appears:
When in partial arming, the zones from 61 to 80 are bypassed (also the combined relays 7 and 8).
DISARMING
The receiver can be disarmed pressing once the disarming button on remote control, at any arming status (TOTAL or PARTIAL).
The reciver emits two “beep” and the display shows “Disarmed” (if no alarm memory):
In case of alarms during arming, at disarming the receiver alerts with some “beep” and the display shows “Alarm Memory”: