8
DOOR CONTROL
This function advice about opened zones at arming.
The receiver emits a special acoustic alert. At this point it is possible to:
1. Confirm: press the arm button on remote control or leave the positive signal on RST input or leave the alert time ends: the opened zones
will be bypassed
2. Disarm: press the disarm button on remote control or remove the positive signal on RST input: the display shows Opened Doors”.
Press the EDIT button, the display shows the radio zone which is opened. In this way it is possible to close the zone and repeat the arm
command without bypass this zone.
3. During the opened door signalling, if the opened zone is known, just close it: in this way it is not necessary to press any button or force
the arming
CTSR AND MINI-C
The CTSR and MINI-C sensors transmit the opened and closed status of their contacts: ON-BOARD REED and EXTERNAL CONTACT.
Depending on the installation (maybe are used both or just one contact) the Opened-Doors advice from these sensors must be set as:
SINGLE: advice IF the ON-BOARD REED is opened (the EXTERNAL CONTACT is ignored)
DOUBLE: advice IF both ON-BOARD REED and EXTERNAL CONTACT are opened (if one of these is closed then no advice)
RECEIVER MODE (IMPULSIVE RELAY)
Set the activation mode of the receiver: MASTER or SLAVE.
Change the activation mode of the ARMING relay (output COM-NC-NA) combined to the remote controls.
MASTER IMPLUSIVE RELAY = NO
The receiver activation depends on remote controls, with two activation modes:
o TOTAL: all the radio zones are active (all the alarm relay outputs are active)
o PARTIAL: only the radio zones 1 ÷ 60 are active, the radio zones 61 ÷ 80 are bypassed (so the alarm relay outputs 7 and
8 stay always closed)
The relay output COM-NC-NA change its status in bistable mode: it is active when the receiver is armed (TOTAL or PARTIAL), at rest
when the receiver is DISARMED.
Connect the output COM-NC-NA of the receiver to the wired arming input of the control panel, the panel will follow the
arming/disarming status of the receiver (MASTER).
If the output P is set as Partial Arming”, it is possible to use this output to partially arm the control panel.
In this mode the receiver can be also armed (only in TOTAL mode) and disarmed by control panel, connecting the arming status
output to the input RST.
When the RST input receives a positive signal from control panel (arming), the receiver mantains the actual arming status from
remote control (TOTAL or PARTIAL). When the control panel removes the positive signal to the RST input (disarming), the receiver
will disarm.
SLAVE IMPULSIVE RELAY = YES
The receiver is activated only via input RST.
Connect the bi-stable input RST of the receiver to the wired arming status output of the control panel: the receiver (SLAVE) will be
activated (only TOTAL) or disarmed from control panel.
The relay output COM-NC-NA change in impulsive mode: active for 2 seconds after any command of a remote control.
Connect the output COM-NC-NA of the receiver to the wired arming input of the control panel; the panel receives a pulse each
time a remote control sends a command: it is possible to arm, partially arm and disarm the system.
Note: using the remote control, the receiver switches the output COM-NC-NA but does not change its status (armed or disarmed)
until a status change of the input RST.