3.4 Boiler Location Considerations
Ambient room temperature always above 32°F (0°C) to
prevent the potential of freezing.
Drainage of water (or water/ antifreeze solution) during
boiler service or from safety relief valve discharge.
Access to system water piping, gas supply, and
electrical service.

capable of supporting the weight of the boiler, water,
and equipment.

wet.
Water, gas, and electrical may connect to either side of
boiler as desired.
Horizontal run to chimney shall be as short as possible.
3 - LOCATING THE BOILER
Items to Avoid
Products Which May Contain These
Items
Areas Where These Items May Be
Found
Chlorine, Fluorine, and Compounds

Chlorinated waxes/cleaners
Chlorine-based swimming pool chemicals
Calcium chloride used for thawing
Sodium chloride used for water softening
Swimming pool or spa chemicals
De-icing salts or chemicals
Carbon Tetrachloride
Swimming pools and pool storage areas


Airborne Particulates
Drywall dust
Road or gravel dust
Dryer lint
Cat litter


Acids, Solvents, etc.
Paint, Varnish, Turpentine, etc.
Cleaning Solvents
Hydrochloric acid/muriatic acid
Cements, adhesives and glues
Photo processing plants
Garages with workshops

establishments
Laundry Chemicals
Laundry detergents, bleaches, fabric
softeners, etc.
Antistatic fabric softeners (dryer sheets)
Dry cleaning/laundry areas and
establishments
Other
Permanent wave solutions
Refrigerants (Freon, etc) (only where
the refrigerant may be leaking from the
appliance)
Beauty shops
Refrigeration repair shops
Notes:


passages possibly resulting in unsafe operation. In this case, unit servicing shall include


the room be generously ventilated (well in excess of combustible air requirements), and
homeowner seal laundry supply containers, and minimize room vapors.
. Piping allowing fresh air in should also be considered. See Section 5-1.
Table 3-1: CONTAMINANTS
System piping exposed to freezing conditions: Use

manufacturer for use with closed water heating system.
Do not use automotive or ethylene glycol.
Maximum recommended mixture 50% glycol.