57
B - Troubleshooting and Error Message
B1 - Error Message
LED Display Description Cause of Error
ERR = L1 Clamp station is 1. MT1 - fuse blown.
not in the home position. 2. LS1 - sensor is bad.
3. MT1 - motor problem.
ERR = L2 Clamp station is 1. MT1 - fuse blown.
not in the left holding 2. LS2 - sensor bad.
position. 3. MT1 - motor problem.
ERR = L3 Nipping station is unable 1. MT2 - fuse blown.
to reach the lowest 2. LS3 - sensor bad.
position. 3. MT2 - motor problem.
ERR = L4 Nipping station is unable 1. MT2 - fuse blown.
to reach the highest 2. LS4 - sensor bad.
position. 3. MT2 - motor problem.
ERR = T1 After warm up more than 1. Heater fuse blown.
one hour, binder is not 2. Temperature switch
ready to bind. bad.
3. Heater bad.
TEMP ERROR Temperature too low. 1. Heater fuse blown.
2. Temperature switch
bad.
3. Heater bad.
HALF00 Skip from Cold to Hot. 1. Stand by sensor bad.
2. Thermostat bad.
Note: Check all electrical connectors of appropriate items when
troubleshooting errors.