60
Check if the hot-melt Yes Thermostat has
ERR=T1 glue has been melted been damaged.
completely ? Change thermostat.
No
Check if the heater No Heater fuse has been
fuse is functioning OK ? damaged.
Change heater fuse.
Yes Heater has been
damaged.
Change heater.
Check if the heater No Heater fuse has
TEMP fuse is functioning OK ? been damaged.
ERROR Change heater fuse.
Yes
Check if the heater No Heater has been
is functioning OK ? damaged.
Change heater.
Yes
Check if thermostat No Thermostat has been
is functioning OK ? damaged.
Change thermostat.
Yes Check the heater
and related circuits.
Check if thermostat No TEMP2 sensor has
HALF00 is functioning OK ? been damaged.
Change TEMP2.
Yes Heater has been
damaged.
Change heater.