50
Problem Potential cause Solution see
sec.
Water comes
out in locations
other than the
spray wand.
Rubber seal not in-
serted.
> Place the rubber seal between
the T-shaped connecting pipe
and the water cut-off valve.
> Tighten the threaded nut.
7
Supply hose not con-
nected correctly.
> Check whether the supply
hose is connected correctly.
> If necessary, connect the sup-
ply hose correctly
Fine filter blocked by
foreign bodies.
> Check whether the fine filter
is blocked by foreign matter.
> Clean the fine filter and re-
install it.
9.1
Fine filter damaged.
> Remove the fine filter and
check whether it is damaged.
> Order a new fine filter.
> Have our Customer Service
install a new fine filter.
9.1