If the value of Park Brake Neutral Delay is set too high, there may be too much rollback
when stopping on a slope. If the value is set too low, the scooter may stop too abruptly.
6.5.6.3 Park Brake Release Delay
Parameter Possible Values Default HHP Lite Std Adv
Park Brake Release Delay 0 - 25500ms 100ms
The Park Brake Release Delay is the interval between when the park brake is released and
when the scooter starts driving.
When the scooter is stopped, and the
throttle is deflected, the park brake is
released immediately but the scooter
will not start driving until the Park
Brake Release Delay has expired. This
is useful for a park brake that has a
slow mechanical release.
Figure 57: Park Brake Release Delay
Set the Park Brake Release Delay to suit the mechanical release speed of the park brake:
set the value high for slow releases, and low or zero for fast releases.
Warning
If the Park Brake Release Delay value is set too high the scooter may begin rolling before the motors start
driving.
GBK51948 RHINO2
Installation Manual Issue 5
Programming - Page 107

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dynamic RHINO2 DS120 and is the answer not in the manual?

Dynamic RHINO2 DS120 Specifications

General IconGeneral
BrandDynamic
ModelRHINO2 DS120
CategoryController
LanguageEnglish

Related product manuals